If there is electromagnetic interference in the Gas Flammability Tester, it will affect the detection signal, and there will be data deviation; if there is a collision or vibration, the device will be disconnected, and the detection will fail; if the environment is too humid or the device is flooded, it may If there is a collision or vibration, the device will be disconnected, and the detection will fail; if the environment is too humid or the device is flooded, it may There is a short circuit in the instrument, or the line resistance value changes, and a detection failure occurs.
8 Tips To Avoid Failure In Gas Flammability Tester:
1. combustible gas Flammability Tester use first to find out what are the leak points of the device, analyze their leakage direction, pressure and other factors, while drawing the distribution of its probe location, according to the severity of the leak is divided into Ⅰ, Ⅱ, Ⅲ three levels.
2. According to the density of the leaking gas, then combined with the trend of air flow, integrated into a three-dimensional flow trend map of the leak, and in its flow downstream location to make the initial set point program.
3. Based on the specific factors such as wind direction and air flow direction of the site, determine the direction of combustible gas leakage if a large amount of leakage occurs.
4. Study whether the leakage state of the leak is microleakage or spray. If it is a micro-leak, the location of the set point should be closer to the leak point. If it is a jet, it should be slightly away from the leak point. Taking these conditions into account, a final pointing plan is developed. In this way, it is possible to estimate the quantity and variety of products to be purchased.
5. For places with hydrogen leaks, the detector should be installed on the plane above the leak point.
6. If there is a possibility of a large combustible gas leak in the premises, a detection point should be set up every 10-20m from each other according to the relevant regulations. For small and discontinuous operation of the pump room, need to pay attention to the possibility of combustible gas leaks, more downwind installation of a detector.
7. Combustible gas content close to or at the lower explosive limit concentration, should not be ignored.
8. When using Gas Flammability Tester for gas density greater than air media, the detector should be installed on the plane below the leak point, while paying attention to the characteristics of the surrounding environment. For places where flammable gases tend to accumulate, special attention should be paid to the setting of safety monitoring points.
Several types of Flammability Tester that customers will purchase.