WelcomeWebsite! If you have any questions, please call !
Flammability tester,burning tester,Fire Retardant Fabrics Tester_QINSUN

Hotline:

Product

News

Company:-Qinsun Instruments Co., Ltd.
Phone:+86-17740808215
Tell:+86-21-6780 0179
Email:info@qinsun-lab.com
Address:No.2578 Minhang District Gu Dai Road, Shanghai

The Standard interpretation of Glow Wire Test Chamber

Position: Home > Technical

The Standard interpretation of Glow Wire Test Chamber

Author: Date :2018-08-16 Views: order
Application:
The Glow Wire Tester is designed to carry out fire hazard testing on electro technical products in accordance with the provisions of International standards.
 
The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire.  The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter. 
 
A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature.  The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior.
 
Technical parameters:
Glow wire  diameter 4mm±0.04mmNi/Cr(80/20), standard   
Temperature range 500 ~ 750℃±10℃;750 ~ 960℃±15℃
Thermocouple diameter 0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40~ 1100°C
Searing Time 30s±0.1s (OMRON H5CN-XAN-Z digital timer, 0-9999s, preset table)
Light-off Time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Fire out time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Ironing into depth  7mm ± 0.5 mm
Sample pressure 1N ± 0.2 N
Test speed 18±3mm/s
Test background black background
Test process automatic control, independent convulsions
Chamber ≥0.5m
Control Using single chip microcomputer + touch screen control
 
Consult standards:
IEC60695 - 2 - 10 / 11 / 12 / 13、IEC60884-1、GB2099.1、IEC60335-1、GB4706.1、VDE0620
Power Supply AC 220V,50Hz
 
Test Procedures:
1, the operation before the preparation
2, be sure to read the using instructions, and follow the instructions step, followed by operation;
3, do not use non-original accessories, so as to avoid danger;
4, glow wire test machine should be put in the room that have the oil ventilation equipment (or with a special ventilation hood in a small laboratory), in order to expel the exhaust after the test.
5, the two matching weights with copper wire (connected to the sample rack) by the left side of the two pulleys (through the corresponding hole) hanging under the bracket plate.
6, according to the standard requirements of interest and clamping samples.
7, close to the adjustment of the switch
A. The nut that is fixed to the switch is loosened and moved left and right;
B. Press the "left button" car automatically forward, when the sample contact with the hot wire, the hand close the switch, so that the car stopped before the fixed and close the switch.
C. Press the "Heating" button to adjust the current adjustment knob. According to the requirements of the sample, adjust the appropriate current value, while the temperature is required to meet the test requirements of the required temperature.
When the test piece touches the glowing wire head, the limit electromagnet is released and the 1N weight can only be moved forward by 7mm.
When the experiment is finished, eject the heating button and then turn the current adjustment knob to the minimum.
 
The Standard interpretation of Glow Wire Test Chamber(图1)

Phone:+86-17740808215 Tell:+86-21-6780 0179 Address:No.2578 Minhang District Gu Dai Road, Shanghai Email:info@qinsun-lab.com sitemap