What oxygen concentration should not fall below during the oxygen index test?

Position: Home > News

What oxygen concentration should not fall below during the oxygen index test?

Author: Date :2023-07-21 Views: order

The Limiting Oxygen Index (LOI) is a test method used to evaluate the flame retardancy of a material and can be used to determine the minimum oxygen concentration at which a material will begin to burn. This test method is commonly used to evaluate the fire resistance of materials such as plastics, rubber and textiles and is one of the more common laboratory test methods.


When performing an oxygen index test, it is important to ensure that the oxygen concentration is within a certain range. Oxygen concentrations that are too low may prevent combustion from continuing or from maintaining sufficient temperature and energy output, resulting in inaccurate test results. Therefore, before conducting an oxygen index test, you need to understand the requirements and points of the test method to ensure the accuracy and reliability of the test results.


According to some common testing standards and laboratory practices, the oxygen concentration should generally be no less than 18% when performing an oxygen index test. This is because the minimum oxygen concentration at which many materials begin to burn is 18%. If the oxygen concentration falls below 18%, the test results may be distorted because combustion may not be sustained or may not be able to maintain sufficient temperature and energy output. Therefore, before performing an oxygen index test, it is necessary to ensure that the test equipment is capable of providing an adequate oxygen concentration and that the oxygen concentration is controlled with the accuracy and stability required for the test.


In addition, some other experimental conditions and operational points need to be noted when conducting the oxygen index test to ensure that the test results are accurate and reliable. For example, it is necessary to ensure that the temperature and humidity of the test room are stable to avoid the influence of environmental factors on the test results. Meanwhile, during the testing process, the form, thickness, size and other elements of the tested material need to be standardized, and the samples need to be prepared and installed in accordance with the testing requirements. In addition, a series of safety measures need to be carried out during the oxygen index test to ensure the safety and reliability of the test.


In conclusion, oxygen index testing is a common laboratory test method used to assess the flame retardancy of materials. When conducting the test, it is necessary to ensure that the oxygen concentration is within a certain range, and pay attention to some other experimental conditions and operational points to ensure the accuracy and reliability of the test results.