Guide on UL94 Horizontal & Vertical Flammability Test

Position: Home > News

Guide on UL94 Horizontal & Vertical Flammability Test

Author: Date :2023-08-24 Views: order

Here's a guide on the UL94 Horizontal & Vertical Flammability Test, summarized within 2000 words:


The UL94 flammability test is an industry standard for assessing the flammability characteristics of plastic materials used in various products. It evaluates the material's resistance to ignition and its ability to self-extinguish after being exposed to a flame. The test is conducted in both horizontal and vertical orientations to measure different aspects of the material's flammability.


1. UL94 Horizontal Flammability Test:

   The UL94 Horizontal Burn Test evaluates the burning behavior of the material when exposed to a horizontal flame. It helps to determine the material's tendency to propagate fire across its surface.


   Procedure:

   - Prepare test specimens: Cut samples with specific dimensions according to the standard.

   - Mount the specimen: Secure it in a horizontal position using a metallic holder.

   - Expose to flame: Apply a flame ignition source to the starting point of the specimen for 30 seconds.

   - Flame extinguishment: Remove the flame and observe the flame propagation and burning duration after flame removal.

   - Drip assessment: Note any dripping of flaming particles or particles that ignite flammable materials below the specimen.

   - Record results: Classify the material based on flame propagation, burning duration, and dripping behavior. Results range from V-0 (best) to V-2 (lowest).


2. UL94 Vertical Flammability Test:

   The UL94 Vertical Burn Test assesses the material's ability to self-extinguish when exposed to a vertical flame. It measures the material's resistance to vertical burning and dripping.


   Procedure:

   - Prepare test specimens: Cut samples according to specified dimensions.

   - Mount the specimen: Vertically suspend it in a test cabinet ensuring a consistent flame exposure.

   - Flame application: Ignite the lower end of the specimen using a flame ignition source.

   - Flame duration: Remove the flame and observe the material's ability to self-extinguish. Measure the time taken for the flame to extinguish.

   - Drip assessment: Note any flaming drips or particles that ignite cotton located below the specimen.

   - Record results: Materials are classified based on burn rate, afterglow time, dripping behavior, and whether ignition of the cotton occurs. Results range from V-0 (best) to V-2 (lowest).

Guide on UL94 Horizontal & Vertical Flammability Test(图1)

It's important to note that passing the UL94 flammability test does not indicate that the material is non-combustible or completely fire-resistant. It provides a relative assessment of the material's resistance to ignition and flame propagation.


Furthermore, it's crucial to consult the official UL94 standard for detailed instructions, including sample dimensions, testing conditions, and specific pass/fail criteria for each classification.


Remember, this guide is a summary, and it's always recommended to refer to the official UL94 standard or consult with a qualified testing laboratory for accurate and up-to-date information related to flammability testing.